Twisted aerial bundled cable overhead transmission line abc electric cable conductors

Twisted aerial bundled cable overhead transmission line abc electric cable conductors

  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
  • Twisted aerial bundled cable overhead transmission line abc electric cable conductors
Twisted aerial bundled cable overhead transmission line abc electric cable conductors
Produktdetails:
Herkunftsort: Henan
Markenname: Sanwu
Zertifizierung: ISO CCC
Modellnummer: ABC
Zahlung und Versand AGB:
Min Bestellmenge: 1000M
Preis: Negotiable
Verpackung Informationen: Standard exportierte hölzerne Trommel oder Spulen
Lieferzeit: 1-15days
Zahlungsbedingungen: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Versorgungsmaterial-Fähigkeit: 200 Tonnen pro Tag
Kontakt
Ausführliche Produkt-Beschreibung
Ort der Vorlage: Henan, China Leiter: 1350 Aluminium
Isoliert: XLPE/PVC Art: Niederspannung
Verpackung: Behandelte hölzerne Trommel Anwendung: Netzverteilung

Twisted aerial bundled cable overhead transmission line abc electric cable conductors

 

1. Application

Aerial Bunched Cable ABC cable primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

2. Specification of Triplex Low Voltage Power Cable

Cable meets or exceeds the following ASTM specifications:
· B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
· B-231 Aluminum Conductors, Concentric-Lay-Stranded.
· B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
· B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
· B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire

 

3. Conductor:

Phase Conductor Bare Neutral Messenger
AAC AAC
ACSR
Alloy

 

4. Service Drop Cable Meets or Exceeds the Following Specifications:

1). Aluminum Wire,1350-H19 for Electrical Purposes;

2). Aluminum Conductors,Concentric-Lay-Stranded;

3). Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR);

4). Concentric-Lay-Stranded 6201-T81 Conductors;

5). Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474;

 

5. Cable's Characteristics:

1). Max.admissible long time operating to conductor:

PVC or PE insulated should not exceed 70℃,XLPE insulated should not exceed 90℃;

2). Installing temperature should not be below -20℃;

3). Admissible bending radius:

When overall-diameter(D)is less than 25mm,it should be not less than 4D;

When overall-diameter(D) is 25mm or more,it should be not less than 6D;

 

Triplex Service Drop

 

Code name AWG or kcmil Bare Neutral Messenger Phase Conductor Weight Allowable Ampacities(A)
ACSR Rated Strength lbs. AAC Insul.Thick.Mm
No.&Dia.Mm No.& Dia.Mm No. & Dia.Mm kg/km XLPE PE
Paludina 2*6AWG+1*6AWG 1*1.68 6*1.68 1190 1*4.11 1.14 166 85 70
Voluta 2*6AWG+1*6AWG 1*1.68 6*1.68 1190 7*1.56 1.14 170 85 70
Whelk 2*4AWG+1*4AWG 1*2.12 6*2.12 1860 1*5.19 1.14 251 115 90
Periwinkle 2*4AWG+1*4AWG 1*2.12 6*2.12 1860 7*1.96 1.14 255 115 90
Conch 2*2AWG+1*2AWG 1*2.67 6*2.67 2850 7*2.47 1.14 389 150 120
Neritina 2*1/0AWG+1*1/0AWG 1*3.37 6*3.37 4380 7*3.12 1.52 624 205 160
Cenia 2*1/0AWG+1*1/0AWG 1*3.37 6*3.37 4380 19*1.89 1.52 625 205 160

 

Duplex Service Drop

Code word AWG or kcmil Bare Neutral Messenger Phase Conductor Weight Allowable Ampacities(A)
ALLOY Rated Strength libs. A AC Insul.Thick.Mm
Number & Dia.Mm Number&Dia.Mm kg/km XLPE PE
Chihuahua 1*6AWG+1*30.58 7*1.68 1110 1*4.11 1.14 98 85 70
Vizsla 1*6AWG+1*30.58 7*1.68 1110 7*1.56 1.14 100 85 70
Harrier 1*4AWG+1*48.69 7*2.12 1760 1*5.19 1.14 149 115 90
Whippet 1*4AWG+1*48.69 7*2.12 1760 7*1.96 1.14 151 115 90
Schnauzer 1*2AWG+1*77.47 7*2.67 2800 7*2.47 1.14 231 150 120
Heeler 1*1/0AWG+1*123.3 7*3.37 4460 19*1.89 1.52 372 205 160

 

Twisted aerial bundled cable overhead transmission line abc electric cable conductors 0